Cent Eur J Public Health 1995, 3(Supplement):S85-S87
The vibrotactile threshold (VT) at the fingertips of chain saw operators
- Institute of Occupational Health and Social Medicine, Johannes Gutenberg University, Mainz, Germany
The vibration sensitivity of the skin at the ten fingertips was tested with 72 chain saw operators examined due to VWF-disease and compared with controls. The vibrotactile perception threshold (frequency f = 125 Hz, load p = 1.3 N) proved to be 3 to 5 times as high for the exposed group compared to controls. There was no correlation between vibration sensitivity and peripheral circulation found in cold provocation test. Two different testing instruments (pallaesthesiometer = vibrotactometer) showed significant differences in results probably due to different technical details of the methods. It may be concluded that a standardization of the instrumentation and method is necessary for testing the vibrotactile perception threshold as a part of the nervous function in a comparable manner.
Zveřejněno: 1. červenec 1995 Zobrazit citaci